[300B SE Valve Amplifier Kit] Analog Metric
www.analogmetric.com
4
THD+N < 5% @1kHz
Maximum Output Power: 8W at 8 Ohms
Output transformer 15-20W:
Primary impedance: 2.5k/3.5k Ohms 120mA
Secondary impedance: 4, 8 and 16 Ohms
Stereo single-end input and output
Power requirements: one or two 300-350V DC (total 250mA), 6.3V AC/DC (1.5A),
and two 5V AC/DC (1.5A).
PCB dimension: 196mm (W) x 175mm (L)
PCB thickness: 2.4mm, double layer, 2oz copper.
PRECAUTIONS
Do not use any body parts to touch the metal parts of the kit after power up or power
off, since the high voltage capacitors may not fully discharge. It may cause serious
electric shock.
Use a power transformer with fuse (3A) socket to limit the supply current in case of
short circuit or incorrect assembly.
Double check the assembled components with the part list.
Do not attempt the measure the voltage by multimeter with hand after power up. The
probes of the multimeter should be mounted by some stands to the points of the
measurement before switching on the power supply.
Turn off the power supply if you observe any smokes or hear strange sound coming
out from the transformer or board. If there is short circuit, the transformer will be
getting very hot shortly.
PROCEDURES
1. Solder the resistors on the top of the board. The resistance label of the Dale resistors
should face upward for easy of future debugging or modification.